Microscopic Particulate Analysis
Technical Document
Introduction
In 1989 the EPA promulgated the Surface Water Treatment Rule (SWTR) in response to the
1986 Amendments to the Safe Drinking Water Act (SDWA). The overall goal of the SWTR is to
protect consumers from surface water pathogens. The SWTR recommends a multiple-barrier
approach including source water protection, filtration and disinfection when surface water
is used as source water for drinking.
The requirements of the SWTR also apply to ground water under the direct influence
(GWUDI) of surface water which may include vertical and horizontal wells, infiltration
galleries, springs, etc. The SWTR required the evaluation of all community ground water
sources for GWUDI by June 29, 1994 and all non-community ground water sources by June 29,
1999.
Typically, GWUDI status is determined by state authorities using a combination of
hydrogeologic criteria, sanitary surveys, well construction logs and analytical testing.
Testing may attempt to prove or disprove direct hydraulic connection between surface and
ground waters by correlating shifts in conductivity, temperature, pH, etc., and may use
Microscopic Particulate Analysis (MPA).
Water supplies identified as being GWUDI must comply with requirements of the SWTR and
treat their source(s) accordingly.
EPA Consensus Method
The EPA Consensus Method for MPA is based on identifying surface water
"bioindicators" such as plant debris, algae, diatoms, insects, rotifers, Giardia
and coccidia which are characteristic of surface waters. In the Consensus Method, risk
scores are assigned to each category of bioindicators. After tabulation of the number and
type of bioindicators observed in a particular sample, an overall risk rating score is
calculated. This score indicates the risk of surface water contamination.
The MPA method involves filtering a minimum of 500 gallons of ground water through a 1
micron (µm) nominal-pore-size fiber wound filter over a maximum 24-hour period. The
filter is then processed in the laboratory by eluting the particles from the fibers,
concentrating the eluant, and microscopically examining slides for bioindicators. The
bioindicators are quantified and used to calculate a relative surface water risk factor as
described above.
It is important to realize that much of the MPA Consensus Method was developed in the
late 1980s and a preliminary draft was published in the 1990 SWTR Guidance Manual.
Thus, Giardia was recognized as a specific surface water pathogen of
interest and was included in the method, whereas Cryptosporidium was included under
the general classification of Coccidia. In addition, the method only suggests
(rather than requires) monoclonal immunofluorescent antibody (IFA) staining for Giardia
or Cryptosporidium, making their detection problematic at best.
In response to subsequent method development, many laboratories, including Analytical
Services, Inc. (ASI) offer the MPA method with and without an added IFA staining
procedure. In our laboratory, an aliquot of the eluted, concentrated and purified
(optional) sample is stained and examined microscopically in accordance with a modified
Information Collection Rule (ICR) procedure. Any observed Giardia cysts or Cryptosporidium
oocysts are enumerated and reported.
The MPA procedure has also been modified and used in several laboratories as a means of
assessing filtration plant performance evaluation (FPPE). Recognizing this application,
the EPA released a modified version called Microscopic Particulate Analysis (MPA) for
Filtration Plant Optimization (FPO) in 1996. For a discussion of this and other treatment
plant optimization techniques, please see ASI Technical Document No. 101, Water Treatment
Plant Optimization Techniques.
Data Interpretation
Interpretation of MPA data is directly dependent on the level of training and
experience of the analyst performing the analysis and writing the report. ASI has analyzed
over 10,000 MPA, Giardia and Cryptosporidium and Filtration Plant
Optimization (FPO) samples since 1990. All ASI analysts who perform MPA have earned
college degrees in microbiology or closely related fields, such as biology, limnology or
aquatic biology and are fully trained on standard procedures and our proprietary Standard
Operating Procedure (SOP) for analyzing MPA samples.
The EPA Consensus Method does not include a thorough Quality Assurance/Quality Control
(QA/QC) section. In response, ASI has instituted a comprehensive QA/QC plan specifically
for MPA sample handling and analysis. As part of this program, ASI has developed an
extensive reference manual, which includes photomicrographs and permanent slides of
relevant bioindicators. This library, our training procedures, and other elements of our
QA/QC plan assures that ASI maintains the high standards our clients have come to expect
and rely on.
Summary
We understand the impact of MPA results on water suppliers and communities nationwide
who rely on ground water sources. Therefore, we provide our clients with explicit reports
that describe the MPA methodology and interpretation of their sample results. As with our
other services, our senior technical staff, directed by Dr. Kristen Tilton, Ph.D.,
M.S.E.L., is available to provide consulting services regarding GWUDI results and answer
any questions or address any concerns that clients may have regarding their samples and/or
source waters.
Relevant Literature
USEPA. 1992. Consensus Method for Determining Groundwaters Under
the Direct Influence of Surface Water Using Microscopic Particulate analysis (MPA). EPA
910/9-92-029.
SAIC. 1997. Final report: Microscopic Particulate Analysis (MPA)
Correlations with Giardia and Cryptosporidium Occurrence in Ground Water
Under the Direct Influence (GWUDI) of Surface Water Sources. EPA Contract No. 68-C6-0059.
USEPA. 1994. National Primary Drinking Water Regulations:
Enhanced Surface Water Treatment Requirements; Proposed Rule. Fed. Reg., 40 CFR,
Parts 141 and 142.
USEPA. 1992. Use of Microbial Risk Assessment in Setting U.S.
Drinking Water Standards. EPA 814/S-92-001.
USEPA. 1996. Microscopic Particulate Analysis (MPA) for
Filtration Plant Optimization. EPA 910-R-96-001.
|